Instrumentation Hardware |
|
|
|
Gauge Snubber |
|
Air Header |
|
Syphone |
|
Condensate Pot |
|
Chemical Injection Quill |
|
|
|
|
Condensate Pot |
|
|
|
Condensate should not be confused with demineralized, de-ionized, make up, or softened water. When the condensate enters the boiler feed pump additionalchemicals are added and the product is now called boiler feed water. |
|
Features : |
|
Use as liquid or condensate traps, seal pots, vapor chambers and knockout pots. |
|
All connectors are furnished with plstic plugs. |
|
Chambers are made from seamless carbon steel pipe and weld caps. All pipe connections are 3000# half-couplings mounted on 90 Degree angle. Extra connections can be furnished upon customer request. |
|
Heat code traceability |
|
All welding as per ASME SEC. IX |
|
All butweld joints will be 100% radiographed |
|
Fillet weld will be D.P. tested. |
|
All material will have mother test certificates. |
|
All condensate pot will be hot dep galvanised. |
|
All threads will be protected with dead plugs / plastic caps. |
|
Piping code compliance ASME B31.1 and PED category I, Module - A. |
|
Optional IBR approval is offered, depending upon customer requirement |
|
|
Technical Specification : |
|
Size : Pipe size 2",3",4" and larger size upon request. |
|
Length : Pipe length 8",10",12" and larger length upon request. |
|
Working pressure : 6000 Psig (413 Bar) |
|
Material of construction : SS 316, SS 304, C.S.,
ASTM A 106 Gr B |
|
Optional Sour Gas service valves are available confirming to NACE Std. MR - 01 - 75 |
|
Pipe Schedule : 40, 80, 160, XX seamless pipe. |
|
Chamber as per ISA RP3 |
|
NPT as per ANSI B1.20.1 taper pipe thread 1/2" furnished. |
|
Socket weld as per ANSI B16.11 |
|
Butt weld as per ANSI B16.9 |
|
All chamber are 100% Factory tested prior to shipment. |
|
|
Application : |
|
Refineries, liquid patroleum gas processing plant, petro-chemical plants, systems difficult to shur off due to solid contents dust, rust, dirt etc. |
|
|
Testing : |
|
Hydrostatic shell test is performed at 1.5 times the working pressure. |
|
|